Tool Box & Terms
The following tools and formulas can help determine the proper product for your application.
FORMULAS
Key:
M = Mesh count
D = Wire Diameter
O = Opening Size
POA = Percent of Open Area
To Calculate Opening: |
||||
| O = |
|
|||
To Calculate Mesh Count: |
||||
| M = |
|
|||
To Calculate Wire Diameter: |
||||
| D = |
|
|||
To Calculate Percent of Open Area: POA = (OM)2 * 100
To Calculate Percent of Open Area: POA = (O/O+D)2 * 100
To Calculate Percent of Open Area: POA = (1-MD)2 * 100
Micron / Inch Conversion
| To Convert | Multiply by | To Determine |
| Inches | 25445 | Microns |
| Micron | 0.00003937 | Inches |